Slot slot-number — FPC slot number:.M20 router—0 through 3.M120 router—0 through 5.MX240 router—0 through 2. On the MX240 router, slot-numbercorresponds to the (DPC slot number. If an MPC is installed, slot-numbercorresponds to the MPC slot number.MX480 router—0 through 5. On the MX480 router, slot-numbercorresponds to the DPC slot number. If an MPC is installed, slot-numbercorresponds to the MPC slot number.MX960 router—0 through 11. On the MX960 router,slot-number corresponds to the DPC slot number. If an MPC is installed,slot-number corresponds to the MPC slot number.MX2020 router—0 through 19.MX2010 router—0 through 9.MX2008 router—0 through 9.TX Matrix and TX Matrix Plus routers only—On theTX Matrix router, if you specify the number of the T640 router byusing the lcc number option (the recommendedmethod), replace slot-number with a value from0 through 7.
Apr 09, 2013 FPC is very useful. The main reason to use FPC is to link it to a real life piece of hardware. What FPC does is it converts midi data for notes (A, A#, B) to samples (the pads). So for example, if you played a 'C' on your keyboard, it would play whatever you map to the 'C' pad, for example a kick.
How To Use Fpc Connector
Otherwise, replace slot-number witha value from 0 through 31.Likewise, on a TX Matrix Plus router, if you specify the numberof the T1600 or T4000 router by using the lcc number option (the recommended method), replace slot-number with a value from 0 through 7. Otherwise, replace slot-number with a value from 0 through 31. In case of TX Matrix Plus routerwith 3D SIBs, replace slot-number with a valuefrom 0 through 63. For example, the followingcommands have the same result. User@host request chassis fpc slot 9 offline.Other routers—0 through 7.QFabric System—Replace slot-number with a value from 0 through 2.EX Series switches:.EX4200 switches in a Virtual Chassis configuration—Replace slot-number with a value from 0 through 9.EX6210 switches—Replace slot-number with a value from 0 through 9. NoteThese commands are not supported for slots 4 and 5 whena Switch Fabric and Routing Engine (SRE) module is installed in thoseslots.
These commands are supported for slots 4 and 5 only if a linecard is installed in them.EX8208 switches—Replace slot-number with a value from 0 through 7.EX8216 switches—Replace slot-number with a value from 0 through 15.EX9204 switches—Replace slot-number with a value from 0 through 2.EX9208 switches—Replace slot-number with a value from 0 through 5.EX9214 switches—Replace slot-number with a value from 0 through 11.PTX5000 Packet Transport Router—Replace slot-number with a value from 0 through 7. Replace number with the followingvalues depending on the LCC configuration:.0 through 3, when T640 routers are connected to a TX Matrixrouter in a routing matrix.0 through 3, when T1600 routers are connected to a TXMatrix Plus router in a routing matrix.0 through 7, when T1600 routers are connected to a TXMatrix Plus router with 3D SIBs in a routing matrix.0, 2, 4, or 6, when T4000 routers are connected to a TXMatrix Plus router with 3D SIBs in a routing matrix.Required Privilege Levelmaintenance.